The NDR Series of DIN rail power supplies is designed specifically for use in industrial applications. The 40 to 63 mm slim form-factor enables the power supplies to be easily installed in small and confined spaces such as cabinets.
The broad operating temperature range of -20 to 70°C means they are capable of operating in harsh environments. The devices have a metal housing, an AC input range from 90 VAC to 264 VAC, and conform to the EN 61000-3-2 standard. In addition, these power supplies feature constant current mode to provide overload protection.
PACKAGE CONTENTS: 1 x NDR-120-48
| Device: | Accessories |
|---|
Features
- DIN-rail mounted power supply
- Slim form factor that is ideal for cabinet installation
- Universal AC power input
- High power conversion efficiency
Technical Specifications
Output Power Parameters
- Wattage:
- NDR-120-24: 120 W
- NDR-120-48: 120 W
- NDR-240-48: 240 W
- Voltage:
- NDR-120-24: 24 VDC
- NDR-120-48: 48 VDC
- NDR-240-48: 48 VDC
- Current Rating:
- NDR-120-24: 0 to 5 A
- NDR-120-48: 0 to 2.5 A
- NDR-240-48: 0 to 5 A
- Ripple and Noise:
- NDR-120-24: 120 mVp-p
- NDR-120-48: 150 mVp-p
- NDR-240-48: 150 mVp-p
- Voltage Adjustment Range:
- NDR-120-24: 24 to 28 VDC
- NDR-120-48: 48 to 55 VDC
- NDR-240-48: 48 to 55 VDC
- Setup/Rise Time at Full Load:
- NDR-120-24: 2500 ms, 60 ms at 115 VAC
- NDR-120-24: 1200 ms, 60 ms at 230 VAC
- NDR-120-48: 2500 ms, 60 ms at 115 VAC
- NDR-120-48: 1200 ms, 60 ms at 230 VAC
- NDR-240-48: 3000 ms, 100 ms at 115 VAC
- NDR-240-48: 1500 ms, 100 ms at 230 VAC
- Typical Hold Up Time at Full Load:
- NDR-120-24: 10 ms at 115 VAC
- NDR-120-24: 16 ms at 230 VAC
- NDR-120-48: 10 ms at 115 VAC
- NDR-120-48: 16 ms at 230 VAC
- NDR-240-48: 22 ms at 115 VAC
- NDR-240-48: 28 ms at 230 VAC
Input Power Parameters
- Typical Efficiency:
- NDR-120-24: 88%
- NDR-120-48: 89%
- NDR-240-48: 90%
- Typical Current:
- NDR-120-24: 1.3 A @ 230 VAC, 2.25 A @ 115 VAC
- NDR-120-48: 1.3 A @ 230 VAC, 2.25 A @ 115 VAC
- NDR-240-48: 1.3 A @ 230 VAC, 2.5 A @ 115 VAC
- Voltage Range:
- 90 to 264 VAC (47 to 63 Hz)
- 127 to 370 VDC
- nrush Current (cold start): 35 A @ 230 VAC, 20 A @ 115 VAC
Overload Protection
- Rated Output Power: 105 to 160%
- Protection Type: Constant current limiting, recovers automatically after fault condition is removed
Overvoltage Protection
- Overvoltage Range:
- NDR-120-24: 29 to 33 V
- NDR-240-48: 56 to 65 V
- NDR-120-48: 56 to 65 V
- Protection Type: Shut down operating voltage, repower on to recover
Physical Characteristics
- Housing: Metal
- Dimensions:
- NDR-120-24: 123.75 x 125.20 x 40 mm (4.87 x 4.93 x 1.57 in)
- NDR-120-48: 123.75 x 125.20 x 40 mm (4.87 x 4.93 x 1.57 in)
- NDR-240-48: 127.81 x 123.75 x 63 mm (5.03 x 4.87 x 2.48 in)
- Weight:
- NDR-120-24: 500 g (1.10 lb)
- NDR-120-48: 500 g (1.10 lb)
- NDR-240-48: 900 g (1.98 lb)
Environmental Limits
- Operating Temperature:
- NDR-120-24: -20 to 70°C (-4 to 158°F)
- NDR-120-48: -20 to 70°C (-4 to 158°F)
- NDR-240-48: -20 to 70°C (-4 to 158°F)
- Storage Temperature: -40 to 85°C (-40 to 185°F)
- Ambient Relative Humidity: 20 to 95% (non-condensing)
- Max. Operating Temperature at Full Load:
- NDR-120-48: 45°C (113°F)
- NDR-120-24: 45°C (113°F)
- NDR-240-48: 50°C (122°F)
Standards and Certifications
- Safety:
- UL 508
- EN 62368-1
- IEC 62368-1
- EMC:
- EN 55032/35
- EN 61000-3-2 Class A
- EN 61000-3-3
- EN IEC 61204-3
- EN IEC 61000-6-2
- EMS:
- IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
- IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
- IEC 61000-4-4 EFT: Power: 2 kV
- IEC 61000-4-5 Surge: Power: 4 kV
- IEC 61000-4-6 CS: 0.15 kHz to 80 MHz: 10 Vrms
- IEC 61000-4-8: 30 A/m
- IEC 61000-4-11
MTBF
- Standards: MIL-HDBK-217F
- Time:
- NDR-120-24: 453,334 hrs
- NDR-120-48: 453,334 hrs
- NDR-240-48: 230,206 hrs
Warranty
- Warranty Period: 3 years