HW Group - SMS-GW3 LTE E plain - 600708
Central GSM-SMS-LTE gateway for HW group sensors. IP sensors connected via LAN. GSM-LTE modem included, external SMA antenna required.
Producentens varenummer:
600708
Har du spørgsmål? Vi vil med glæde rådgive dig! → Kontaktformular
Produktinformation "HW Group - SMS-GW3 LTE E plain - 600708"
SMS-GW3 LTE is a central text messaging (SMS) gateway that HWg devices and applications on the same network can use to dial numbers or send SMS alerts.
SMS-GW3 LTE can also be used to send text messages by HWg software applications (HWg-Trigger, HWg-DCD2) and the SensDesk.com online portal.
Each unit can send its alarm messages to different phone numbers. SMS-GW3 LTE is a LAN gateway for sending alarm SMS from HW group devices. Alarm messages can be sent from any HW group monitoring device. No additional software required, works over LAN at the box-2-box (peer-to-peer) level.
Applications and usage:
SMS-GW3 LTE can also be used to send text messages by HWg software applications (HWg-Trigger, HWg-DCD2) and the SensDesk.com online portal.
Each unit can send its alarm messages to different phone numbers. SMS-GW3 LTE is a LAN gateway for sending alarm SMS from HW group devices. Alarm messages can be sent from any HW group monitoring device. No additional software required, works over LAN at the box-2-box (peer-to-peer) level.
Applications and usage:
- One SMS gateway for the entire network with web-based configuration.
- No additional software required to send SMS.
- The phone number of the SMS recipient is configured in the sending device.
- Supports an "SMS + Ring" function.
- Connection for external antenna.
- Quad-band GSM.
- Examples for programmers available in the HWg SDK (Borland C++, MS Visual C, VB, C#, PHP, JAVA and more).
- LTE connection
| Bandwidth: | 4G |
|---|---|
| Connection: | Ethernet Port, USB Port |
| Option: | SIM card slot |
| Options: | 2G/3G, LTE |
| Power Supply: | 12V DC |
| Temperature Range: | Standard Temperature Range |
Features
- Ethernet: 10/100 Mbit/s, LTE
- Connected via LTE and GSM/GPRS. List of APNs available worldwide
- GSM antenna: External 3m cable, SMA
- Can be used to send SMS from the following software and services: HWg-Trigger software, HWg-DCD software, Nagios monitoring software (Netways: notify-poseidon-sms.pl), www.SensDesk.com online service.
- M2M communication protocols: SNMP, XML, netGSM (http, SOAP)
- Internal memory for outgoing SMS queue: 100 messages
- Support for programmers: HWg-SDK
- Mechanical: 76 x 93 x 28 mm, wall-mountable, fits on a DIN rail
Technical details
Connection
Ethernet
100 Mbit/s
IP protocols
ARP, TCP/IP (HTTP, netGSM)
Interface *
FDD LTE band: B1/B3/B5/B7/B8/B20
WCDMA band: B1/B5/B8
GSM band: 900/1800 GPRS multi-slot class 12
Class 4 (33 dBm +-2 dB) for GSM900
Class 1 (30 dBm +-2 dB) for DCS1800
Class E2 (27 dBm +-3 dB) for GSM900 8-PSK
Class E2 (26 dBm +-3 dB) for DCS1800 8-PSK
Class 3 (24 dBm +1/-3 dB) for WCDMA bands
Class 3 (23 dBm +-2 dB) for LTE FDD bands
Antenna
External, SMA quad-band, 3m
* Choose the model that fits your location. Ask your dealer for the appropriate model
Message queue
SMS queue memory
100 messages
Parameters
Power
9-15 V / 0.4 A
Consumption
250mA
Dimensions
98 x 92 x 33 (WxHxD) / 222g
Environment
From -10 °C to +65 °C (from +14 °F to +149 °F)
Operating environment
-30°C - 80°C / 5%RH - 95%RH
Supported SW
HWg-PDMS, HWg-Trigger
Connection
Ethernet
100 Mbit/s
IP protocols
ARP, TCP/IP (HTTP, netGSM)
Interface *
FDD LTE band: B1/B3/B5/B7/B8/B20
WCDMA band: B1/B5/B8
GSM band: 900/1800 GPRS multi-slot class 12
Class 4 (33 dBm +-2 dB) for GSM900
Class 1 (30 dBm +-2 dB) for DCS1800
Class E2 (27 dBm +-3 dB) for GSM900 8-PSK
Class E2 (26 dBm +-3 dB) for DCS1800 8-PSK
Class 3 (24 dBm +1/-3 dB) for WCDMA bands
Class 3 (23 dBm +-2 dB) for LTE FDD bands
Antenna
External, SMA quad-band, 3m
* Choose the model that fits your location. Ask your dealer for the appropriate model
Message queue
SMS queue memory
100 messages
Parameters
Power
9-15 V / 0.4 A
Consumption
250mA
Dimensions
98 x 92 x 33 (WxHxD) / 222g
Environment
From -10 °C to +65 °C (from +14 °F to +149 °F)
Operating environment
-30°C - 80°C / 5%RH - 95%RH
Supported SW
HWg-PDMS, HWg-Trigger