MOXA - ioLogik E2210-T
Universal controller, 12 DIs, 8 DOs, Click&Go, -40 to 75°C operating temperature
Listepris:
3.620,70 kr.*
Forhandlerpris - Login
1 stykker til rådighed, leveringstid: 2 - 3 arbejdsdage

Producentens varenummer:
ioLogik E2210-T
Vores artikelnummer:
12928
Har du spørgsmål? Vi vil med glæde rådgive dig! → Kontaktformular
Produktinformation "MOXA - ioLogik E2210-T"
Moxa’s ioLogik E2200 Series Ethernet Remote I/O is a PC-based data acquisition and control device that uses proactive, event-based reporting to control I/O devices and features the Click&Go programming interface. Unlike traditional PLCs, which are passive and must poll for data, Moxa’s ioLogik E2200 Series will, when paired with our MX-AOPC UA Server, communicate with SCADA systems using active messaging that is pushed to the server only when state changes or configured events occur. Additionally, the ioLogik E2200 features SNMP for communications and control using an NMS (Network Management System), allowing IT professionals to configure the device to push I/O status reports according to configured specifications. This report-by-exception approach, which is new to PC-based monitoring, requires far less bandwidth than traditional polling methods.
Scope of delivery: MOXA - ioLogik E2210-T
Scope of delivery: MOXA - ioLogik E2210-T
I/O Interfaces: | Digital Input, Digital Output, I/O Sink |
---|---|
Interface: | Serial RS485 |
Protocol: | API, ModBus, SNMP, TCP, UDP |
Temperature Range: | Extended Temperature Range |
Features
PC-Free Alarm and Control Intelligence
This device supports simple yet powerful Click&Go™ technology to configure event-driven reports and alarms delivered over email, TCP/UDP, or SNMP traps, giving you a powerful and effective tool for delivering timestamped status updates in real time.
With built-in Click&Go™ intelligence, this device can be configured for simple outputs paired up with simple input triggers without the need for a PC controller. This allows it to be configured to automatically report I/O events according to conditions specified by the user.
SNMP for Ethernet Device Management
By using SNMP, IT engineers can configure the device to deliver alarms (traps) for specific I/O events, or use it to read or write directly to the I/O registers. For the strongest security, the device features SNMPv3, with authentication and encryption. With Moxa’s SNMP-capable I/O, even IT professionals can easily integrate industrial sensors and servos over an Ethernet backbone, and with its strong network management tools, it is ideal for a wide variety of industrial applications, including environmental monitoring, telecommunications, power production and delivery, and transportation.
Push Technology for Events and Alarms
When used with MX-AOPC UA Server, devices can use active push communications when communicating changes in state and/or events to a SCADA system. Unlike a polling system, when using a push architecture for communications with a SCADA system, messages will only be delivered when changes in state or configured events occur, resulting in higher accuracy and lower amounts of data that need to be transferred.
PC-Free Alarm and Control Intelligence
This device supports simple yet powerful Click&Go™ technology to configure event-driven reports and alarms delivered over email, TCP/UDP, or SNMP traps, giving you a powerful and effective tool for delivering timestamped status updates in real time.
With built-in Click&Go™ intelligence, this device can be configured for simple outputs paired up with simple input triggers without the need for a PC controller. This allows it to be configured to automatically report I/O events according to conditions specified by the user.
SNMP for Ethernet Device Management
By using SNMP, IT engineers can configure the device to deliver alarms (traps) for specific I/O events, or use it to read or write directly to the I/O registers. For the strongest security, the device features SNMPv3, with authentication and encryption. With Moxa’s SNMP-capable I/O, even IT professionals can easily integrate industrial sensors and servos over an Ethernet backbone, and with its strong network management tools, it is ideal for a wide variety of industrial applications, including environmental monitoring, telecommunications, power production and delivery, and transportation.
Push Technology for Events and Alarms
When used with MX-AOPC UA Server, devices can use active push communications when communicating changes in state and/or events to a SCADA system. Unlike a polling system, when using a push architecture for communications with a SCADA system, messages will only be delivered when changes in state or configured events occur, resulting in higher accuracy and lower amounts of data that need to be transferred.
Techncial details
Control Logic
Language: Click&Go
Input/Output Interface
Digital Input Channels: 12
Digital Output Channels: 8
Buttons: Reset button
Rotary Switch: 0 to 9
Isolation: 3k VDC or 2k Vrms
Digital Inputs
Connector: Screw-fastened Euroblock terminal
Sensor Type: Dry contact, Wet contact (NPN)
I/O Mode: DI or event counter
Dry Contact: On: short to GND; Off: open
Wet Contact (DI to GND): On: 0 to 3 VDC; Off: 10 to 30 VDC
Counter Frequency: 900 Hz
Digital Filtering Time Interval: Software configurable
Points per COM: 12 channels
Digital Outputs
Connector: Screw-fastened Euroblock terminal
I/O Type: Sink
I/O Mode: DO or pulse output
Current Rating: 200 mA per channel
Pulse Output Frequency: 1 kHz
Over-Current Protection: 0.65 A per channel @ 25°C
Over-Temperature Shutdown: 175°C (min.)
Over-Voltage Protection: 45 VDC (typical)
LED Interface
LED Indicators: PWR, RDY, Serial, I/O Status
Ethernet Interface
10/100BaseT(X) Ports (RJ45 connector): 1
Magnetic Isolation Protection: 1.5 kV (built-in)
Ethernet Software Features
Configuration Options: Windows Utility (ioAdmin), Web Console (HTTP)
Industrial Protocols: Modbus TCP Server (Slave), SNMPv1/v2c/v3, SNMPv1 Trap, Moxa AOPC (Active Tag), MXIO Library, CGI commands
Management: BOOTP, IPv4, SMTP, DHCP Client, HTTP, TCP/IP
MIB: Device Settings MIB
Time Management: SNTP
Security Functions
Authentication: Local database
Encryption: HMAC
Security Protocols: SNMPv3
Modbus TCP
Functions Supported: 1, 2, 3, 4, 5, 6, 15, 16
Mode: Server (Slave)
Serial Interface
Connector: Terminal block
Serial Standards: RS-485
No. of Ports: 1
Baudrate: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
Parity: None
Data Bits: 8
Stop Bits: 1
Flow Control: None
Serial Signals
RS-485-2w: Data+, Data-, GND
Serial Software Features
Industrial Protocols: Modbus RTU Master
Platform
Real-time Clock (RTC): Real-time clock with battery backup
Power Parameters
Power Connector: Screw-fastened Euroblock terminal
No. of Power Inputs: 1
Input Voltage: 12 to 36 VDC
Power Consumption: 203 mA @ 24 VDC
Physical Characteristics
Dimensions: 115 x 79 x 45.6 mm (4.53 x 3.11 x 1.80 in)
Weight: 250 g (0.55 lb)
Installation: DIN-rail mounting, Wall mounting
Wiring: I/O cable, 16 to 26 AWG; Power cable, 16 to 26 AWG
Housing: Plastic
Environmental Limits
Operating Temperature: -40 to 75°C (-40 to 167°F)
Storage Temperature (package included): -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Altitude: 2000 m
Control Logic
Language: Click&Go
Input/Output Interface
Digital Input Channels: 12
Digital Output Channels: 8
Buttons: Reset button
Rotary Switch: 0 to 9
Isolation: 3k VDC or 2k Vrms
Digital Inputs
Connector: Screw-fastened Euroblock terminal
Sensor Type: Dry contact, Wet contact (NPN)
I/O Mode: DI or event counter
Dry Contact: On: short to GND; Off: open
Wet Contact (DI to GND): On: 0 to 3 VDC; Off: 10 to 30 VDC
Counter Frequency: 900 Hz
Digital Filtering Time Interval: Software configurable
Points per COM: 12 channels
Digital Outputs
Connector: Screw-fastened Euroblock terminal
I/O Type: Sink
I/O Mode: DO or pulse output
Current Rating: 200 mA per channel
Pulse Output Frequency: 1 kHz
Over-Current Protection: 0.65 A per channel @ 25°C
Over-Temperature Shutdown: 175°C (min.)
Over-Voltage Protection: 45 VDC (typical)
LED Interface
LED Indicators: PWR, RDY, Serial, I/O Status
Ethernet Interface
10/100BaseT(X) Ports (RJ45 connector): 1
Magnetic Isolation Protection: 1.5 kV (built-in)
Ethernet Software Features
Configuration Options: Windows Utility (ioAdmin), Web Console (HTTP)
Industrial Protocols: Modbus TCP Server (Slave), SNMPv1/v2c/v3, SNMPv1 Trap, Moxa AOPC (Active Tag), MXIO Library, CGI commands
Management: BOOTP, IPv4, SMTP, DHCP Client, HTTP, TCP/IP
MIB: Device Settings MIB
Time Management: SNTP
Security Functions
Authentication: Local database
Encryption: HMAC
Security Protocols: SNMPv3
Modbus TCP
Functions Supported: 1, 2, 3, 4, 5, 6, 15, 16
Mode: Server (Slave)
Serial Interface
Connector: Terminal block
Serial Standards: RS-485
No. of Ports: 1
Baudrate: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
Parity: None
Data Bits: 8
Stop Bits: 1
Flow Control: None
Serial Signals
RS-485-2w: Data+, Data-, GND
Serial Software Features
Industrial Protocols: Modbus RTU Master
Platform
Real-time Clock (RTC): Real-time clock with battery backup
Power Parameters
Power Connector: Screw-fastened Euroblock terminal
No. of Power Inputs: 1
Input Voltage: 12 to 36 VDC
Power Consumption: 203 mA @ 24 VDC
Physical Characteristics
Dimensions: 115 x 79 x 45.6 mm (4.53 x 3.11 x 1.80 in)
Weight: 250 g (0.55 lb)
Installation: DIN-rail mounting, Wall mounting
Wiring: I/O cable, 16 to 26 AWG; Power cable, 16 to 26 AWG
Housing: Plastic
Environmental Limits
Operating Temperature: -40 to 75°C (-40 to 167°F)
Storage Temperature (package included): -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Altitude: 2000 m