Listepris:
5.058,55 kr.*
Forhandlerpris - Login
Leveringstid: Varer er bestilt, vil være tilgængelige igen inden længe

Producentens varenummer:
NPort 5430
Vores artikelnummer:
10190
Har du spørgsmål? Vi vil med glæde rådgive dig! → Kontaktformular
Produktinformation "MOXA - NPort 5430"
NPort 5400 device servers offer many useful features for serial-to-Ethernet applications, including an independent operating mode for each serial port, a user-friendly LCD panel for easy installation, two DC inputs and adjustable termination and pull high / low resistors.
Scope of delivery: MOXA NPort 5430
Scope of delivery: MOXA NPort 5430
Connection: | 10 / 100-TX (RL45) |
---|---|
Power Supply: | External |
Protocol: | RS 422 / 485 |
Serial Ports: | 4 Ports |
Features
Network readiness for up to 4 serial devices.
NPort 5400 device servers can conveniently and transparently connect up to four serial devices to an Ethernet network, allowing you to network your existing serial devices with just a basic configuration. Data transfer between the serial and Ethernet interfaces is bi-directional. By using NPort® device servers, you not only protect your current hardware investment, but also enable future network expansion. You can both centralise the management of your serial devices and distribute management hosts across the network.
Independent operating mode for each serial port
NPort 5400 device servers can be used to connect different devices for remote data retrieval or event handling over a TCP / IP network. Each serial port on the NPort 5400 operates independently for maximum versatility. For example, port 1 can operate in driver mode, port 2 in TCP server mode and ports 3 and 4 in TCP client mode.
User-friendly LCD panel for easy installation
The top panel of the NPort 5400 incorporates an LCD panel with four buttons for data entry, configuration and operating mode selection. The LCD panel displays the server name, serial number and IP address, and can be used to enter or change parameters such as IP address, netmask and gateway. (The LCD panel is not available in wide temperature models).
Dual DC inputs
NPort 5400 device servers support dual power sources by providing both a DC terminal block input and a DC power connector input. Providing two types of power inputs gives users greater flexibility for use with different applications.
Adjustable termination and high / low pull resistors
The NPort 5400 series provides adjustable termination and pull high / low resistors for RS-485 applications. In some critical environments, termination resistors may be required to prevent serial signal reflection, and pull high / low resistors may need to be adjusted to maintain electrical signal integrity. Since no set of resistor values is universally compatible with all environments, the NPort® 5400 has four sets of DIP switches on the bottom to adjust the termination and pull high / low resistor values.
Network readiness for up to 4 serial devices.
NPort 5400 device servers can conveniently and transparently connect up to four serial devices to an Ethernet network, allowing you to network your existing serial devices with just a basic configuration. Data transfer between the serial and Ethernet interfaces is bi-directional. By using NPort® device servers, you not only protect your current hardware investment, but also enable future network expansion. You can both centralise the management of your serial devices and distribute management hosts across the network.
Independent operating mode for each serial port
NPort 5400 device servers can be used to connect different devices for remote data retrieval or event handling over a TCP / IP network. Each serial port on the NPort 5400 operates independently for maximum versatility. For example, port 1 can operate in driver mode, port 2 in TCP server mode and ports 3 and 4 in TCP client mode.
User-friendly LCD panel for easy installation
The top panel of the NPort 5400 incorporates an LCD panel with four buttons for data entry, configuration and operating mode selection. The LCD panel displays the server name, serial number and IP address, and can be used to enter or change parameters such as IP address, netmask and gateway. (The LCD panel is not available in wide temperature models).
Dual DC inputs
NPort 5400 device servers support dual power sources by providing both a DC terminal block input and a DC power connector input. Providing two types of power inputs gives users greater flexibility for use with different applications.
Adjustable termination and high / low pull resistors
The NPort 5400 series provides adjustable termination and pull high / low resistors for RS-485 applications. In some critical environments, termination resistors may be required to prevent serial signal reflection, and pull high / low resistors may need to be adjusted to maintain electrical signal integrity. Since no set of resistor values is universally compatible with all environments, the NPort® 5400 has four sets of DIP switches on the bottom to adjust the termination and pull high / low resistor values.
Technical details
Ethernet interface
Ethernet interface
- 10 / 100BaseT (X) ports (RJ45 connector): 1
- Magnetic isolation protection: 1.5 kV (built-in)
- Setting options: Telnet console, Windows utility, web console (HTTP / HTTPS)
- Windows Real COM drivers: Windows 95/98 / ME / NT / 2000, Windows XP / 2003 / Vista / 2008/7/8 / 8.1 / 10 (x86 / x64), Windows 2008 R2 / 2012/2012 R2 / 2016/2019 (x64), Windows Embedded CE 5.0 / 6.0, Windows XP Embedded
- Linux Real TTY drivers: kernel versions: 2.4.x, 2.6.x, 3.x, 4.x and 5.x.
- Fixed TTY drivers: SCO UNIX, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X.
- Management: ARP, BOOTP, DHCP-Client, DNS, HTTP, HTTPS, ICMP, IPv4, LLDP, Rtelnet, SMTP, SNMPv1 / v2c, TCP / IP, Telnet, UDP
- Timing: SNTP
- Filter: IGMP v1 / v2
- Android API: Android 3.1.x and higher
- Connector: Terminal Block
- Serial standards: RS-422, RS-485
- Number of ports: 4
- Baud rate: Supports standard baud rates (unit = bps): 50, 75, 110, 134, 150, 300, 600, 1200, 1800, 2400, 4800, 7200, 9600, 19200, 38400, 57600, 115200, 230,4 k, 460,8 k, 921,6 k
- Sequence control: XON / XOFF
- Parity: None, even, odd, space, mark
- Stop bits: 1, 1.5, 2
- Data Bits: 5, 6, 7, 8
- Operating modes: Disabled, Ethernet Modem, Pair Connection, Real COM, Reverse Telnet, TCP Client, TCP Server, UDP
- Terminator for RS-485: 120 Ohm
- Pull High / Low resistor for RS-485: 1 kiloohm, 150 kiloohm
- RS-485 data direction control: ADDC® (automatic data direction control)
- RS-422: Tx +, Tx-, Rx +, Rx-, GND
- RS-485-4w: Tx +, Tx-, Rx +, Rx-, GND
- RS-485-2w: Data +, Data-, GND
- Connector: 1 removable 3-contact terminal strip
- Input voltage: 12 to 48 VDC
- Input current: 320 mA at 12 VDC
- Number of current inputs: 2
- Automatic restart trigger: Built-in WDT
- Alarm tools: Built-in buzzer and RTC (real time clock)
- Housing: Metal
- Interactive interface: LCD display, push buttons for configuration
- Installation: Desktop, DIN-rail mounting (with optional kit), wall mounting
- Dimensions (with ears): 181 x 103 x 33 mm (7,14 x 4,06 x 1,30 inc.)
- Dimensions (without ears): 158 x 103 x 33 mm (6.22 x 4.06 x 1.30 inc.)
- Weight: 740 g
- Operating temperature: 0 to 55 ° C (32 to 131 ° F)
- Storage temperature: -40 to 75 ° C (-40 to 167 ° F)
- Relative humidity: 5 to 95% (non-condensing)